多焦视网膜电图对近视眼的临床研究
CSTR:
作者:
作者单位:

作者简介:

通讯作者:

中图分类号:

R778.1

基金项目:


Multifocal electroretinogram in myopia
Author:
Affiliation:

Fund Project:

  • 摘要
  • |
  • 图/表
  • |
  • 访问统计
  • |
  • 参考文献
  • |
  • 相似文献
  • |
  • 引证文献
  • |
  • 资源附件
  • |
  • 文章评论
    摘要:

    目的:测试近视眼患者的多焦视网膜电图的改变。方法:应用美国EDI公司生产的VERISScience4.2多焦视网膜电图检查仪对24例48眼近视患者,22例44眼正常者进行检测,分析其总体和6个环形视网膜区域的反应。结果:近视患者总体和6个环形视网膜区域的反应密度均低于正常者,潜伏期无明显改变。结论:近视患者多焦视网膜电图的反应密度下降,这种改变主要是由于视网膜感受器功能受损所致。

    Abstract:

    AIM:To measure and compare the difference of multifocal electroretinogram between normal subjects and patients with myopia.·METHODS:Twenty-two cases(44 eyes) of normal subjects and twenty-four cases (48 eyes) with myopia were tested with VERIS Science 4.2 made by EDI company of America.All trace grouping waveform and six ring average response were determined.We studied the differences of response densities and latencies between normal and myopic groups.·RESULTS:The response densities of all trace grouping waveform and six ring average response in myopia were decreased while the latencies were not changed.·CONCLUSION:The response densities of multifocal electroretinogram in myopic eyes were reduced and resulted predominantly from retinal receptors function loss.

    参考文献
    相似文献
    引证文献
引用本文

陈忠飞,杨云东,徐深.多焦视网膜电图对近视眼的临床研究.国际眼科杂志, 2010,10(2):360-361.

复制
分享
文章指标
  • 点击次数:
  • 下载次数:
  • HTML阅读次数:
  • 引用次数:
历史
  • 收稿日期:
  • 最后修改日期:
  • 录用日期:
  • 在线发布日期:
  • 出版日期:
文章二维码