Abstract:AIM: To evaluate the visual outcome of Oculentis Mplus intraocular lens(IOL).
METHODS: Totally 20 eyes in 20 patients received phacoemulsification and Oculentis Mplus intraocular lens implantation were as test group, and 20 eyes(Aspira-aA IOL)were as control group. The following postoperative examinations were performed after operation for 3mo: uncorrected visual acuity of distance and near, refractive results, UBM examination, the rate of wearing spectacles and the complications.
RESULTS: At 3mo after surgery, distance visual acuity of test group with Oculentis Mplus IOL were 0.10±0.03,the difference with control group was not significant(t=1.74, P>0.05). Eyes in test group had an uncorrected near acuity 0.11±0.04, the difference with control group was significant(t=15.53, P<0.05). The rate of wearing spectacles was 5% in test group and 100% in control group. The rate of uncomfortableness was 5% in test group.
CONCLUSION: The implantation of Oculentis Mplus IOL not only has a good distance uncorrected visual acuity, but also with better near visual acuity. The surgery is safe, reliable and no special complication induced.