RTVue XR和Keratograph测量下泪河高度的重复性和再现性比较
CSTR:
作者:
作者单位:

作者简介:

通讯作者:

中图分类号:

基金项目:

广东省深圳市宝安区科技计划项目(No.2013165)


Repeatability and reproducibility of tear meniscus height with RTVue XR and Keratograph
Author:
Affiliation:

Fund Project:

Science and Technology Plan Project of Baoan District of Shenzhen(No.2013165)

  • 摘要
  • |
  • 图/表
  • |
  • 访问统计
  • |
  • 参考文献
  • |
  • 相似文献
  • |
  • 引证文献
  • |
  • 资源附件
  • |
  • 文章评论
    摘要:

    目的:比较RTVue XR和Keratograph眼表综合分析仪测量下泪河高度(LTMH)的差异,评估两种设备在初始眼以及FS-LASIK术后眼中测量LTMH的重复性和再现性。

    方法:选择2019-01在广州爱尔眼科医院就诊的初始眼以及FS-LASIK术后眼各52只。分别使用RTVue XR和Keratograph眼表综合分析仪进行LTMH测量。比较两种设备测量值的差异。采用组内标准偏差(Sw),重复测量重复度(2.77Sw),变异系数(CoV)和组内相关系数(ICC)评价两种设备测量的重复性和再现性。

    结果:初始眼组中,RTVue XR和Keratograph测量的LTMH分别为261.12±80.29、235.05±78.40μm; 平均CoV为5.55%、14.90%; 平均ICC为0.98、0.87。FS-LASIK眼组中,RTVue XR和Keratograph测量的LTMH分别为234.55±68.38、208.22±73.85μm; 平均CoV为5.29%、16.16%; 平均ICC为0.97、0.87。

    结论:在初始眼及FS-LASIK术后眼中,RTVue XR测量的LTMH值较Keratograph测量值偏大约25μm,测量的信度更高。RTVue XR可以用于临床上初始眼以及FS-LASIK术后眼的LTMH的评估。

    Abstract:

    AIM: To observe the agreement of the lower tear meniscus height(LTMH)measurements using RTVue XR and Keratograph ocular surface analyzer, and to compare intraobserver repeatability and interobserver reproducibility between the two devices in the virginal and FS-LASIK eyes.

    METHODS: Totally 52 virginal eyes and 52 FS-LASIK eyes were included during January 2019 in Guangzhou Aier Eye Hospital. LTMH measurements were performed using RTVue XR and Keratograph Ocular Surface Analyzer. A paired t-test was used to compare the difference between LTMH values using the two devices. The with-subject standard deviation(Sw), test-retest repeatability(2.77Sw), coefficient of variation(CoV)and intraclass correlation coefficient(ICC)were calculated to evaluate the repeatability and reproducibility.

    RESULTS: In the virginal eyes group, the average LTMH obtained with RTVue XR and Keratograph were 261.12±80.29μm and 235.05±78.40μm, respectively. CoV and ICC were 5.55% and 0.98 for RTVue XR, 14.90% and 0.87 for Keratograph, respectively. In the FS-LASIK group, the average LTMH were 234.55±68.38μm and 208.22±73.85μm, respectively. CoV and ICC were 5.29% and 0.97 for RTVue XR, 16.16% and 0.87 for Keratograph, respectively.

    CONCLUSION: In the virginal and FS-LASIK eyes, the LTMH value obtained with RTVue XR is 25μm greater than Keratograph. RTVue XR has a better reliability than Keratograph and can be used to measure the LTMH.

    参考文献
    相似文献
    引证文献
引用本文

樊利敏,吴璇璇,王铮. RTVue XR和Keratograph测量下泪河高度的重复性和再现性比较.国际眼科杂志, 2019,19(7):1191-1195.

复制
分享
文章指标
  • 点击次数:
  • 下载次数:
  • HTML阅读次数:
  • 引用次数:
历史
  • 收稿日期:2019-03-06
  • 最后修改日期:2019-05-30
  • 录用日期:
  • 在线发布日期: 2019-06-21
  • 出版日期:
文章二维码