National Natural Science Foundation of China(No.81700873); Key Research and Development Program of Hebei Province(No.18277754D); Medical Science Research Project Plan of Hebei Province(No.20200842); Research Program of Hebei Administration of Traditional Chinese Medicine(No.2020553); Science and Technology Support Program of Xingtai City(No.2016ZC262)

  • 摘要
  • |
  • 图/表
  • |
  • 访问统计
  • |
  • 参考文献
  • |
  • 相似文献
  • |
  • 引证文献
  • |
  • 资源附件
  • |
  • 文章评论
    摘要:

    目的:评估FS-LASIK手术在制作角膜瓣过程中不透明气泡层(OBL)的发生对准分子激光机眼球旋转追踪补偿的影响。

    方法:前瞻性临床研究。随机抽取2019-07/09在我院行FS-LASIK手术200例400眼。统计FS-LASIK术中OBL的总体发生率、角膜瓣外OBL发生率、角膜瓣内OBL发生率、动态自旋跟踪矫正(DCC)和静态自旋追踪矫正(SCC)的运行成功率,并分析OBL对DCC和SCC运行的影响。

    结果:本研究共发生OBL 183眼,总体OBL发生率为45.8%, DCC成功运行397眼,总体DCC运行成功率为99.2%; SCC成功运行的手术共计为293眼,总体SCC运行成功率为73.2%; 总体OBL、角膜瓣外OBL、角膜瓣内OBL对DCC的运行成败均无影响(P>0.05),但对SCC的运行成败均有影响(P<0.05),OBL发生会导致SCC运行失败。

    结论:在制作角膜瓣过程中OBL的发生可能会导致FS-LASIK准分子激光机SCC运行的失败。

    Abstract:

    AIM: To evaluate the effect of opaque bubble layer(OBL)on the ocular cylotorsion compensation during FS-LASIK procedures.

    METHODS: Prospectively clinical study. From July 2019 to September 2019, two-hundred FS-LASIK patients(400 eyes)were randomly included into this study. The total OBL incidence, flap-out OBL incidence, flap-in OBL incidence, incidence of dynamic cyclotorsion component(DCC)and incidence of static cyclotorsion component(SCC)were statistically analyzed.

    RESULTS: OBL developed in 183 eyes of 400 FS-LASIK eyes, with a total OBL incidence of 45.8%. DCC was successfully performed on 397 eyes, with a total DCC incidence of 99.2%. SCC was successfully performed on 293 eyes, with a total SCC incidence of 73.2%. Neither flap-out OBL nor flap-in OBL could disturb the successful implementation of DCC during the operation(P>0.05). Both flap-out OBL and flap-in OBL could impact the SCC implementation and make it fail(P<0.05).

    CONCLUSION: OBL can result in failure of SCC implementation during the FS-LASIK procedures.