OQSAⅡ评估高度近视并发白内障患者植入不同MIOL术后视觉质量
CSTR:
作者:
作者单位:

作者简介:

通讯作者:

中图分类号:

基金项目:

2019年潍坊市科技发展计划项目(No.2019YX043)


Evaluation of visual quality in cataract patients with high myopia after different MIOL implantation by OQSAⅡ
Author:
Affiliation:

Fund Project:

Weifang Science and Technology Development Plan Project in 2019(No.2019YX043)

  • 摘要
  • |
  • 图/表
  • |
  • 访问统计
  • |
  • 参考文献
  • |
  • 相似文献
  • |
  • 引证文献
  • |
  • 资源附件
  • |
  • 文章评论
    摘要:

    目的:应用双通道客观视觉质量分析系统(OQSAⅡ)测量高度近视并发白内障患者植入区域折射型和衍射折射型多焦点人工晶状体(MIOL)术后的视觉质量。

    方法:回顾性研究。选取2019-01/2020-01在我院诊断为高度近视并发白内障行飞秒激光辅助的白内障超声乳化吸除联合MIOL植入术的患者38例44眼。根据植入MIOL的不同分为区域折射组(19例22眼)和衍射折射组(19例22眼)。术后随访3mo,比较两组患者视力,OQASⅡ测量客观视觉质量,对患者主观视觉质量进行问卷调查,记录患者视近脱镜率、视觉干扰症状及满意度。

    结果:术后3mo,两组患者裸眼远视力(UCDVA)、裸眼中视力(UCIVA)及裸眼近视力(UCNVA)无差异(P>0.05),最佳矫正远视力(BCDVA)及该矫正状态下的中距离(BCIVA)和近距离视力(BCNVA)均无差异(P>0.05)。区域折射组和衍射折射组客观散射指数(OSI)分别是1.97±1.10和2.07±1.02(P=0.755),MTF cut off分别为31.89±14.61和33.17±9.83c/deg(P=0.734)。两组患者OV100%、OV20%、OV9%、主观视近脱镜率、视觉干扰症状及满意度比较均无差异(均P >0.05)。

    结论:高度近视并发白内障患者植入区域折射和衍射折射型MIOL术后均能够获得较好的远、中及近距离视力和视觉质量,OQASⅡ能够客观反映术后视觉质量。

    Abstract:

    AIM: To compare the visual quality of cataract patients with high myopia after regional refraction or diffraction refraction multi-focal intraocular lens(MIOL)implantation by using objective optical quality analysis system(OQASⅡ).

    METHODS: Retrospective study. From January 2019 to January 2020, 38 patients with 44 eyes diagnosed as cataract with high myopia that had underwent femtosecond laser-assisted phacoemulsification combined with intraocular lens implantation in our hospital were selected. Regional refraction MIOL group includes 19 cases 22 eyes, and diffraction refraction MIOL group includes 19 cases 22 eyes. After 3mo follow up, OQASⅡ measured objective visual quality and questionnaire surveys were conducted on the subjective visual quality of the patients. Record the patient's subjective near spectacle independence, visual disturbance symptoms, and satisfaction.

    RESULTS: After 3mo follow-up, the uncorrected distance visual acuity(UCDVA), uncorrected intermediate visual acuity(UCIVA)and uncorrected near visual acuity(UCNVA)had no difference(P>0.05), and the best corrected distance visual acuity(BCDVA), best corrected intermediate visual acuity(BCIVA)and best corrected near visual acuity(BCNVA)had no difference(P>0.05). The objective scattering index(OSI)values of regional refraction MIOL group and diffraction refraction MIOL group were 1.97±1.10 and 2.07±1.02(P=0.755). The MTF cut off of regional refraction MIOL group and diffraction refraction MIOL group were 31.89±14.61 and 33.17±9.83c/deg, respectively(P=0.734). There was no statistically significant difference in OV100%, OV20%, OV9% between the two groups(all P>0.05).

    CONCLUSION: Cataract patients with high myopia can obtain better distance, middle and diffraction refraction MIOL implantation, and OQASⅡ can objectively reflect the visual quality after cataract surgery.

    参考文献
    相似文献
    引证文献
引用本文

高婧,常鲁,姜鹏飞,等. OQSAⅡ评估高度近视并发白内障患者植入不同MIOL术后视觉质量.国际眼科杂志, 2021,21(7):1284-1287.

复制
分享
文章指标
  • 点击次数:
  • 下载次数:
  • HTML阅读次数:
  • 引用次数:
历史
  • 收稿日期:
  • 最后修改日期:2021-06-07
  • 录用日期:
  • 在线发布日期: 2021-06-24
  • 出版日期:
文章二维码