英文论著

Evaluation of a screening software for amblyopia

Lei Xi1,2,3, Feng Zhao1, Jun-Wen Zeng1

 

This study aim to investigate the efficacy of a novel screening software for amblyopia. Totally 324 (176 males and 148 females) preschoolers aged 3-6 years old from outpatient department participated in the study in 2017. They were assessed for amblyopia by their parents, using the screening software and were reevaluated by ophthalmologists with professional eye tests. Sensitivity, specificity of the screening software was validated by comparing the results from the screening software and those from the professional tests. Four amblyopes were found by professional tests. And 3 of them were detected by the screening software. The sensitivity, specificity were 75.0%, 90.0%, respectively. Professional tests cost an average of US Dollar (US$) 607/case of amblyopia detected, whereas the cost was near US$ 0/case for the screening software, except the cost of software development. The results from this pilot study indicate that the screening software for amblyopia is a simple, and highly effective, which offers a new option of amblyopia screening for developing countries.

 

一种新型弱视筛查软件的有效性测评研究

席蕾1,2,3,赵峰1,曾骏文1

 该文对一种新型弱视筛查软件的有效性进行了评估,研究共纳入324名于2017年眼科门诊就诊的3-6岁学龄前儿童(176名男性,148名女性)。参与研究的儿童由家长独立使用弱视筛查软件判断是否可能患有弱视,随后再由专业的眼科医师对所有儿童再次进行专业的眼科检查,通过比较筛选软件和专业眼科检查的结果,验证筛选软件的敏感性和特异性。结果显示,专业的眼科检查诊断了4名弱视患儿,而弱视筛查软件发现了其中3名,软件筛查的敏感性和特异性分别为75%90%。此外,专业的眼科检查诊断每例弱视平均需要607美元,而软件筛查除了开发成本外,其余花费几乎为零。因此,弱视筛查软件可作为一种简单,高效且性价比较高的弱视筛查手段,尤其适用于发展中国家。

http://ies.ijo.cn/cn_publish/2019/12/201912002.pdf



栏目:临床研究

 

题目:波前像差光路系统检测IOL倾斜和偏心对光学成像质量的影响

作者:李承霖,崔  红,李正日,金  花,金海燕,汝新宇,邓文庆,吴成哲,李英俊

基金项目:国家自然科学基金委员会资助项目(No.8156016781960182

推荐意见:随着人工晶状体(IOL)设计和材料的日趋完善,目前可供临床选择的IOL种类繁多,但新兴的IOL在眼内是否能真正实现其模拟生理晶状体的功能而达到提高视觉质量的目的仍需深入研究。临床观察发现,术中植入的IOL在眼内会出现不同程度的倾斜和偏心,可引起术后波前像差改变,视力下降等现象,故准确测量IOL的倾斜和偏心值,观察术后光学成像质量的变化,对于评价手术方案及选择植入功能性IOL的类型具有重要的指导意义。文章通过实验室搭建Hartmann-Shack IOL波前像差光路系统探讨三种不同类型(球面、非球面单焦点、非球面多焦点)IOL在偏心和倾斜情况下对光学成像质量的影响,结果表明具有-0.27μm球差的非球面IOL倾斜度小于,偏心小于0.4mm时可获得比球面IOL更好的光学成像质量。

 

http://ies.ijo.cn/cn_publish/2019/12/201912017.pdf



临床研究

 

Peters异常PITX2PAX6基因型表型分析

永,卢国华,谢 阳,孙新成,黄丽琴 

基金项目:常州市卫生局指导性项目(No.WZ201315

Peters异常(Peters’anomalyPA)是较少见的眼前段发育不良性眼病。目前国外有Peters异常相关致病基因PITX2PAX6等的分子遗传学的研究;而国内Peters异常PITX2PAX6基因的报道很少。文章2016-01-01/2019-03-30于常州市第二人民医院和第三人民医院就诊的15Peters异常患者进行PITX2PAX6基因突变分析,结果发现PA患者15例中检测到1个新PITX2基因突变,丰富了PITX2基因突变频谱,进一步明确了PA合并Axenfeld-Rieger综合征眼病的临床特点,为该种少见眼病的临床诊断和发病原因提供了依据。

 

http://ies.ijo.cn/cn_publish/2019/12/201912028.pdf



栏目:临床报告

 

极低出生体质量儿出生后体质量增长速率与阈值病变早产儿视网膜病变的相关性研究


周真宝,庄静宜,陈 焓,刘显勇,李清煌,卓


推荐理由:文章回顾性分析2017-01/ 2018-12于厦门大学附属第一医院住院的极低出生体质量早产儿(出生体质量<1500g386例,所有入组的早产儿均采用RetCam3进行眼底筛查,观察视网膜血管发育情况。依筛查结果,将入组早产儿分为TDROP组(阈值病变早产儿视网膜病变)88例和无ROP298例,分析其性别、出生体质量、胎龄、分娩方式、是否吸氧、Apgar评分、是否试管婴儿、是否双生、有无合并新生儿肺炎及出生后1~4wk的体质量增长速率与TDROP的相关性。多因素Logistic回归分析显示,出生体质量、出生胎龄、出生后2wk体质量增长速率、是否合并吸氧与TDROP显著相关,通过进一步分析出生后2wk体质量增长速率的ROC曲线,显示AUC0.710,诊断临界值为4.14g/d,敏感性为70.8%,特异性为65.9%。结果表明,出生体质量是TDROP发生的独立危险因素之一,而极低出生体质量儿出生2wk体质量增长速率与TDROP的发生显著相关,对其发生具有一定的预测价值。

 

http://ies.ijo.cn/cn_publish/2019/12/201912037.pdf


更多优秀全文免费阅读:http://ies.ijo.cn/gjykcn/ch/reader/issue_list.aspx?year_id=2019&quarter_id=12

 

发布日期:2019-11-21浏览次数:

主管单位:陕西省卫生健康委员会

主办单位:中华医学会西安分会

出版单位:《国际眼科》杂志社(IJO Press)

社长/总编:胡秀文

主编:惠延年 Peter Wiedemann

编辑部主任:彭娟

刊期:月刊

语种:中英文混合

按检索
检索词
  • 浏览排行
  • 引用排行
  • 文章排行