Retinometer examination in predicting the value of visual acuity after cataract surgery
Author:
Corresponding Author:

Affiliation:

Clc Number:

R779.66

Fund Project:

  • Article
  • |
  • Figures
  • |
  • Metrics
  • |
  • Reference
  • |
  • Related
  • |
  • Cited by
  • |
  • Materials
  • |
  • Comments
    Abstract:

    ·AIM:To evaluate a retinal visual acuity meter(retino-meter)in predicting the value of visual acuity after cataract surgery.·METHODS:Ninety-three patients(106 eyes)with various types of cataract were randomly selected,preoperative visual acuity tested by LAMBDA 100 retinometer in patients was compared with postoperative 3 months corrected visual acuity.·RESULTS:Of 106 eyes,12(11.3%)had equal preo-perative predicted and postoperative visual acuity,69(65.1%)had better visual acuity than predicted visual acuity(false-negative),25(23.6%)had postoperative visual acuity lower than predicted(false-positive).·CONCLUSION:LAMBDA 100 clinical detection of retinal visual acuity meter has an excellent result in determining the non-dense non-mature cataract with high accuracy.The existence of false-negative and false-positive cases in different eyes provides a basis for intrao-perative implantation of different intraocular lens.·

    Reference
    Related
    Cited by
Get Citation

Ying-Hong Lin, Peng Zhuang, Cai-Hui Zheng, et al. Retinometer examination in predicting the value of visual acuity after cataract surgery. Guoji Yanke Zazhi( Int Eye Sci) 2010;10(3):547-548