Analysis of factors correlated with central corneal thickness in myopia
Author:
Corresponding Author:

Affiliation:

Clc Number:

R778.11

Fund Project:

  • Article
  • |
  • Figures
  • |
  • Metrics
  • |
  • Reference
  • |
  • Related
  • |
  • Cited by
  • |
  • Materials
  • |
  • Comments
    Abstract:

    AIM: To investigate the factors correlated with central corneal thickness(CCT) in patients with myopia. METHODS: A total of 2 027 patients 4 002 eyes of myopia were examined. CCT was measured by ultrasound corneal pachymeter. Refraction was measured by automatic refractor. Intraocular pressure (IOP) was mea-sured by non-contact tonometer. Corneal endothelia was measured by corneal topography. History of wearing soft contact lens and other factors were also analyzed. RESULTS: A negative correlation was found between CCT and history of wearing soft contact lens (t=- 4.475, P=0.000).The correlation between IOP and CCT was significant (r=2.856, P=0.000), and. CCT was nega-tively correlated with refraction (r=- 0.662, P=0.000). No signifi-cant correlation was found between CCT and corneal endothelia. CONCLUSION: The CCT in patients of myopia was correlated with history of wearing soft contact lens,refraction and IOP.

    Reference
    Related
    Cited by
Get Citation

Yu-Chan Li, Yue Zhang. Analysis of factors correlated with central corneal thickness in myopia. Guoji Yanke Zazhi( Int Eye Sci) 2010;10(4):665-666