Comparison of anterior segment changes before and after laser peripheral iridotomy by anterior segment optical coherence tomography in eyes with primary angle-closure glaucoma
Author:
Corresponding Author:

Affiliation:

Clc Number:

Fund Project:

  • Article
  • |
  • Figures
  • |
  • Metrics
  • |
  • Reference
  • |
  • Related
  • |
  • Cited by
  • |
  • Materials
  • |
  • Comments
    Abstract:

    AIM: To evaluate the changes of anterior segment configuration after laser peripheral iridotomy(LPI)in patients with primary angle-closure glaucoma(PACG)by using anterior segment optical coherence tomography(AS-OCT).

    METHODS: This retrospective self control study consisted of forty-two eyes of 30 patients with PACG whose open angles were more than 180 degree. Central anterior chamber depth(ACD), opening distance(AOD), trabecular iris area(TISA)were measured using AS-OCT before and four weeks after LPI.

    RESULTS: The parameters of AS-OCT on baseline were AOD 0.172±0.078μm, TISA 0.066±0.025mm2 at 500μm anterior to sclera spur, and AOD 0.268±0.133μm, TISA 0.122±0.045mm2 at 750μm. After LPI, the parameters were AOD 0.277±0.105μm, TISA 0.113±0.041mm2 at 500μm, and AOD 0.388±0.154μm, TISA 0.194±0.063mm2 at 750μm, which were significantly increased compared with the baseline(P<0.05). There was no significant difference on ACD before and after LPI(P=0.108).

    CONCLUSION: PACG can be controlled by LPI resulting in an increase of AOD, TISA but not ACD.

    Reference
    Related
    Cited by
Get Citation

Xiao-Tong Zhuang, Feng-Min Wang, Wei Xiao. Comparison of anterior segment changes before and after laser peripheral iridotomy by anterior segment optical coherence tomography in eyes with primary angle-closure glaucoma. Guoji Yanke Zazhi( Int Eye Sci) 2012;12(11):2151-2153〖JP〗

Copy
Share
Article Metrics
  • Abstract:
  • PDF:
  • HTML:
  • Cited by:
Publication History
  • Received:July 13,2012
  • Revised:October 12,2012
  • Adopted:
  • Online:
  • Published: