Preventive effect of sharp-edged capsule tension ring on posterior capsule opacification
Author:
  • Article
  • | |
  • Metrics
  • |
  • Reference
  • |
  • Related
  • |
  • Cited by
  • | |
  • Comments
    Abstract:

    AIM: To evaluate the effect of sharp-edged capsule tension ring(CTR)on posterior capsule opacification(PCO).

    METHODS: Twenty eyes of New Zealand white rabbits were randomly divided into two groups. After phacoemulsification, the experimental group was implanted with CTR and Crane OV-55C intraocular lens(IOL), and the control group was implanted with Crane OV-55C IOL only. Complications and PCO were observed by slit lamp microscope. Three months after surgery, light microscope and transmission electron microscope examinations were performed.

    RESULTS: There was no statistically significant difference between the experimental group and the control group about PCO and Soemmering's ring formation(P>0.05). Pathological evaluations revealed lens epithelial cells(LECs)accumulated at the equatorial capsule forming a large Soemmering's ring and abundant LECs were migrated onto the posterior capsule forming a thick layer in both experimental group and the control group.

    CONCLUSION: Sharp-edged CTR fail to retard PCO formation and development in rabbits and it is nessessary to improve it.

    Reference
    Related
    Cited by
Get Citation

Hai-Hong Shi, Jian Wu, Ling Yang. ,/et al.Preventive effect of sharp-edged capsule tension ring on posterior capsule opacification. Guoji Yanke Zazhi( Int Eye Sci) 2013;13(9):1762-1764

Copy
Share
Article Metrics
  • Abstract:
  • PDF:
  • HTML:
  • Cited by:
Publication History
  • Received:April 16,2013
  • Revised:August 18,2013
  • Online: August 26,2013