Comparison of different phaco techniques in coaxial micro-incision cataract surgery
Author:
  • Article
  • | |
  • Metrics
  • |
  • Reference [15]
  • |
  • Related [20]
  • | | |
  • Comments
    Abstract:

    AIM: To compare the efficiency of coaxial micro-incision cataract surgery(MICS)performed by 3 phacoemulsification techniques(phaco-chop, divide-and- conquer and stop-and-chop).

    METHODS: It was a perspective and randomized clinical trial. Totally 135 patients with age-related cataract were selected randomly and underwent MICS. According to the lens nuclear opacity(NO)of LOCSⅢ grading standards, it can be divided into 3 groups as NO2, NO3 and NO4 group. All groups were randomly subdivided into 3 groups(phaco-chop, divide-and-conquer and stop-and-chop group). The observation target included best-corrected visual acuity(BCVA), central corneal thickness(CCT)and endothelial cell count(ECC)before operation and 1mo postoperation, ultrasound time(UST), cumulative dissipated energy(CDE), estimated fluied used(EFU)in operation and complications.

    RESULTS:In lens nuclear opacity NO4 coaxial micro-incision phacoemulsification, phaco-chop group showed significantly less UST, CDE and EFU than the divide-and-conquer and stop-and-chop groups(P<0.05)and the ratio of endothelial cell loss was significantly lower in the phaco-chop group than in the divide-and-conquer and stop-and-chop groups 1mo after surgery(P<0.05). However, after 1mo surgery, BCVA and CCT among three chop technique groups in different lens nuclear opacity groups had no significant differences(P>0.05).

    CONCLUSION: All 3 techniques may be effective for coaxialmicroincision cataract surgery in mild and moderate nuclear opacity cataracts. However, in eyes with severe nuclear opacity cataract, the phaco-chop technique can be more effective for phacoemulsification, and less corneal endothelial damage.

    Reference
    1 Lee KM, Kwon HG, Joo CK. Microcoaxial cataract surgery outcomes: comparison of 1.8mm system and 2.2mm system. J Cataract Refract Surg 2009; 35(5):874–880
    2 Mahdy MAES, Eid MZ, Mohammed MAB, et al. Relationship between endothelial cell loss and microcoaxial phacoemulsification parameters in noncomplicated cataract surgery. Clin Ophthalmol 2012; 6:503-510
    3 Fine IH, Packer M, Hoffman RS. Use of power modulations in phacoemulsification: choo-choo chop and flip phacoemulsification. J Cataract Refract Surg 2001; 27(2):188-197
    4 Can I, Takmaz T, Cakici F, et al. Comparison of Nagahara phaco-chop and stop-and-chop phacoemulsification nucleotomy techniques. J Cataract Refract Surg 2004; 30(3):663-668
    5 Vajpayee RB, Kumar A, Dada T, et al. Phaco-chop versus stop-and-chop nucleotomy for phacoemulsification. J Cataract Refract Surg 2000; 26(11):1638-1641
    6孟志为,杨丽霞,胥亚男.超声乳化白内障手术对年龄相关性白内障患者角膜内皮细胞的影响.国际眼科杂志 2010; 10(5):942-943
    7马烈,刘芳. 白内障超声乳化术中角膜内皮细胞损害的相关因素分析. 国际眼科杂志2012; 12(1):90-92
    8晏晓明,李海丽.超声乳化术与角膜内皮细胞变化的影响因素分析.中国实用眼科杂志2003; 10(21):781-783
    9 Wong T, Hingorani M, Lee V. Phacoemulsification time and power requirements in phaco chop and divide and conquer nucleofractis techniques. J Cataract Refract Surg 2000; 26(9):1374-1378
    10宋旭东,施玉英,朱晓青,等. 劈核技术在硬核白内障超声乳化手术中的应用. 中华眼科杂志1999; 35:88-90
    11 Park JH, Lee SM, Kwon JW,et al. Ultrasound energy in phacoemulsification:a comparative analysis of phaco-chop and stop-and-chop techniques according to the degree of nuclear density. Ophthalmic Surg Lasers Imaging 2010; 41(2):236-241
    12 Kim EC, Byun YS, Kim MS. Microincision versus small-incision coaxial cataract surgery using different power modes for hard nuclear cataract. J Cataract Refract Surg 2011; 37(10):1799-1805
    13 Hwang HS, Kim EC, Kim MS. Drill-and-crack technique for nuclear disassembly of hard nucleus. J Cataract Refract Surg 2010; 36(10):1627-1630
    14 Kim HK. Decrease and conquer: phacoemulsification technique for hard nucleus cataracts. J Cataract Refract Surg 2009; 35(10):1665-1670
    15 Storr-Paulsen A, Norregaard JC, Ahmed S, et al. Endothelial cell damage after cataract surgery: divide-and-conquer versus phaco-chop technique. J Cataract Refract Surg 2008; 34(6):996-1000
    Cited by
    Comments
    Comments
    分享到微博
    Submit
Get Citation

Yan-Li Zhou, Yong Wang, Xian-Yi Bao,/et al.Comparison of different phaco techniques in coaxial micro-incision cataract surgery. Guoji Yanke Zazhi( Int Eye Sci) 2014;14(4):614-617

Copy
Share
Article Metrics
  • Abstract:1735
  • PDF: 1094
  • HTML: 0
  • Cited by: 0
Publication History
  • Received:January 06,2014
  • Revised:March 17,2014
  • Online: March 24,2014