    Abstract:

    AIM: To determine whether the 23-gauge(23G)vitrecomy cutter could replace scissors in conventional 20-gauge(20G)pars plana vitrectomy for treating severe proliferative diabetic retinopathy(PDR).

    METHODS:Non-comparative interventional case series. Totally 27 eyes of 27 patients with PDR stageⅥ confirmed by funduscopy and B-ultrasound scan were enrolled. They underwent 20G vitrectomy, in which 23G vitrectomy cutter replaced scissors to remove neuvascular membrane. All 27 eyes received complete panretinal photocoagulation, 17 eyes received no tamponade, 6 eyes were 12% C3F8 tamponade, 4 eyes were filled with silicone oil. The follow up time was 3mo. The operation duration time, iatrogenic retinal tear and retinal bleeding need electric coagulation, best corrected visual acuity(BCVA), retinal reattachment were analyzed.

    RESULTS: The operative time was 35-120(average 79.19±29.82)min; intraoperative iatrogenic retinal breaks were detected in 2 eyes(7%). At the end of 3mo follow up, BCVA>0.1 were in 9 eyes, from 0.05-0.1 in 10 eyes, <0.05 in 8 eyes. Retinal reattached in 25 eyes(93%), still detached in other 2 eyes with silicone oil.

    CONCLUSION: The 23G vitrectomy cutter could replace scissors in conventional 20G pars plana vitrectomy for treating severe PDR.

    Reference
    1杨琼,魏文斌.玻璃体手术治疗严重增生性糖尿病视网膜病变合并视网膜脱离的效果.眼科2011; 20(2):106-108
    2刘敬花,李松峰,卢海.23G微创玻璃体切割术在增生性糖尿病视网膜病变治疗中的应用.眼科新进展2012; 32(11):1067-1073
    3 Eckardt C.Transconjunctival sutureless 23-gauge vitrectomy. Retina 2005; 25(2):208-211
    4刘海芸,宋正宇,刘堃,等.23G和20G玻璃体切割手术治疗糖尿病视网膜病变的有效性和安全性比较.中华眼底病杂志2012; 28(2):138-141
    5 Khanduja S,Kakkar A,Majumdar S,et al.Small gauge vitrectomy:Recent update. Oman J Ophthalmol 2013; 6(1):3-11
    6彭亚军,韩丽荣.氩激光超全视网膜光凝术治疗新生血管性青光眼.第二军医大学学报1999; 20(5):320