Clinical observation of orthokeratology on anterior segment parameters by Sirius anterior system
Author:
Corresponding Author:

Affiliation:

Clc Number:

Fund Project:

  • Article
  • |
  • Figures
  • |
  • Metrics
  • |
  • Reference
  • |
  • Related
  • |
  • Cited by
  • |
  • Materials
  • |
  • Comments
    Abstract:

    AIM:To investigate the changes in anterior segment parameters by Sirius anterior system after orthokeratology and the possible mechanisms.

    METHODS: Twenty-eight patients(56 eyes)with myopia in our hospital from August 2014 to October 2014 were included. Spherical equivalent were -3.83±1.19D. Data of central corneal thickness(CCT), anterior chamber depth(ACD), anterior corneal curvature(a-K)and posterior corneal curvature(p-K)were collected and analyzed at before, 1d, 1wk and 3mo after orthokeratology.

    RESULTS: After orthokeratology, spherical equivalent of all eyes decreased to predicted level. There were no significant differences in CCT and p-K between different times(P>0.05). There were significant differences in a-K between different times except between 1wk and 3mo after orthokeratology(P<0.05). There were significant differences in ACD between before and 1wk after, between 1d and 3mo after, between 1wk and 3mo after orthokeratology(P<0.05). There were correlations between CCT before orthokeratology(CCTpre)and the change at 3mo after orthokeratology(CCTc-3mo), between ACD before orthokeratology(ACDpre)and the change at 1d after orthokeratology(ACDc-1d), between a-K before orthokeratology(a-Kpre)and the changes at 1d(a-Kc-1d), 1wk(a-Kc-1wk)and 3mo(a-Kc-3mo)after, respectively(all P<0.05). Multiple linear regression suggested that a-Kc-1d(P=0.016), a-Kc-1wk(P=0.047)were correlated with a-Kpre and axial, respectively. And there were correlations between a-Kpre and a-Kc-3mo(P=0.024), between ACDpre and ACDc-1d(P=0.036), between CCTpre and CCTc-3mo(P=0.012), respectively.

    CONCLUSION: CCT, ACD and p-K has no significant changes after orthokeratology, while there is significant difference in a-K, which is considered one of the most key factor in orthokeratology. Sirius anterior system for examination before orthokeratology and postoperative assessment, non-invasive, reliable and has a good clinical value.

    Reference
    Related
    Cited by
Get Citation

Di Shen, Tan Long, Wei Wei. Clinical observation of orthokeratology on anterior segment parameters by Sirius anterior system. Guoji Yanke Zazhi( Int Eye Sci) 2015;15(6):1016-1019

Copy
Share
Article Metrics
  • Abstract:
  • PDF:
  • HTML:
  • Cited by:
Publication History
  • Received:March 10,2015
  • Revised:May 14,2015
  • Adopted:
  • Online: June 01,2015
  • Published: