Efficacy of iris location to femtosecond-combined wavefront guided LASIK for myopia and astigmatism
Author:
  • Article
  • | |
  • Metrics
  • |
  • Reference [16]
  • |
  • Related [20]
  • | | |
  • Comments
    Abstract:

    AIM:To observe effect of the iris location to femtosecond-combined wavefront guided LASIK for myopia and astigmatism.

    METHODS:The patients with astigmatism >1.0D during the same time and followed up for 1a were selected. A total of 129 eyes in 67 patients were treated under iris location with femtosecond-combined wavefront guided LASIK(experimental group)and 161 eyes in 82 cases with femtosecond-combined wavefront guided LASIK(control group). Laser cutting went with the same laser machine. The uncorrected visual acuity(UCVA), best corrected visual acuity(BCVA), and wavefront aberration between the two groups were compared at 1, 3, 6mo and 1a after surgery.

    RESULTS:At 1 and 3mo after surgery, the number of patients with better postoperative UCVA than preoperative BCVA between the two group showed a statistically significant difference(χ2=6.423, P=0.011,χ2=14.431, P=0.01); at 1d and 1mo after surgery, the residual astigmatism showed a statistically significant difference between two groups(t=1.98, P<0.05; t=2.23, P<0.05). At 3, 6mo and 1a after surgery, the differences on the change of residual astigmatism between the two groups weren't significant(P>0.05). At 6mo and 1a after surgery, the differences on UCVA between the two groups weren't significant(P>0.05). Until 1a after surgery, the root mean square(RMS)of high order wavefront aberration of the two groups, spherical aberration and coma aberration(COMA)were all enhanced compared to before surgery(P<0.05). At 1, 3mo after surgery, the RMS showed a statistically significant difference between two groups(P<0.05). At 1, 3, 6mo, 1a after surgery, the increase of COMA in experimental group was significantly lower than that in control group(P<0.05).

    CONCLUSION:Iris location technology applied in femtosecond-combined wavefront guided LASIK for myopia and astigmatism, can make the vision recovery faster, the RMS of high order and COMA increase less, the residual astigmatism less, show better and more stable treatment effect.

    Reference
    1 Marcos S,Barbero S,Lorente L, et al. Optical response to LASIK surgery fot myopia from total and corneal aberration measurements. Invest Ophthalmol Vis Sci 2001; 42(13):3349-3356
    2 Oshika T,Miyata K,Tokunaga T, et al. Higher order wavefront aberrations of cornea and magnitude of refractive correction in laser in situ keratomileusi. Ophthalmology 2002; 109(6):1154-1158
    3辛宝莉,刘苏冰,聂晓丽,等.虹膜定位联合波前像差引导的LASIK术中眼球旋转的临床观察. 眼科新进展2010; 30(4): 377-380
    4熊宁,刘怡,王平. 波前像差引导准分子激光原位角膜磨镶术治疗近视散光的疗效分析.眼科新进展2007; 27(6):452-454
    5 Hori- Komai Y,Sakai C,Toda I, et al. Detection of cyclotorsional rotation during excimer laser ablation in LASIK. J Refract Surg 2007; 23(9):911-915
    6林巧雅,李学喜,胡俊. 头位偏斜和眼球旋转对LASIK 手术效果的影响.中国实用眼科杂志2012; 30(8):941-944
    7蔡劲锋,朱凤,贾婷,等. LASIK 术中眼球旋转的临床观察.国际眼科杂志2009; 9(5):987-988
    8 De Ortueta D,Pavlidis M. LASIK treatment of mixed astigmatism. J Refract Surg 2007; 23(4):328-329
    9 Gatinel D,Adam PA,Chaabouni S,et al. Comparison of corneal and total ocular aberrations before and after myopic LASIK. J Refract Surg 2010; 26(5):333-340
    10 Wang Y,Zhao K, Jin Y, et al. Changes of higher order aberration with various pupil sizes in the myopic eye. J Refract Surg 2003; 19(2):S270-274
    11 Yang X,Wang Y,Zhao K, et al. Comparison of higher-order aberration and optical quality after Epi-LASIK and LASIK for myopia.Graefes Arch Clin Exp Ophthalmol 2011; 249(2):281-288
    12薛丽霞.波前像差引导LASIK治疗近视散光疗效分析.中国实用眼科杂志2009; 27(1):73-74
    13 Smadja D,Santhiago MR,Mello GR. Corneal higher order aberrations after myopic wavefront-optimized ablation.J Refract Surg 2013; 29(1):42-48
    14夏丽坤,周晶,周佳子,等. 虹膜定位技术主动校正LASIK术中眼球旋转对近视散光患者术后残余散光度数及高阶像差的影响. 眼科新进展 2010; 30(6):544-545
    15周胜,王铮,王蓓,等. 飞秒激光辅助个体化准分子激光原位角膜磨镶术疗效观察.中国实用眼科杂志2008; 26(4):323-326
    16李耀宇.眼波前引导的屈光手术学.北京:人民军医出版社2009:230-231
    Cited by
    Comments
    Comments
    分享到微博
    Submit
Get Citation

Ke-Jie Lin, Jun Chen, Wen Lin,/et al.Efficacy of iris location to femtosecond-combined wavefront guided LASIK for myopia and astigmatism. Guoji Yanke Zazhi( Int Eye Sci) 2016;16(6):1056-1059

Copy
Share
Article Metrics
  • Abstract:1572
  • PDF: 1214
  • HTML: 0
  • Cited by: 0
Publication History
  • Received:January 30,2016
  • Revised:May 16,2016
  • Online: May 31,2016