Comparison of early visual quality between PPCIOL implantation and femtosecond laser LASIK
Author:
Corresponding Author:

Affiliation:

Clc Number:

Fund Project:

  • Article
  • |
  • Figures
  • |
  • Metrics
  • |
  • Reference
  • |
  • Related
  • |
  • Cited by
  • |
  • Materials
  • |
  • Comments
    Abstract:

    AIM: To compare the effects of posterior chamber intraocular lens implantation(PPCIOL)and femtosecond laser LASIK in the treatment of high myopia on postoperative visual quality.

    METHODS: Randomly selected 83 patients with 168 eyes with high myopia from 2015-06/2017-06 in our hospital, they were divided into two groups according to the treatment. Group A was treated with PPCIOL, and group B was treated with femtosecond laser LASIK. The efficacy index, safety index, visual acuity and diopter, high-order aberration changes, contrast sensitivity values, and complications in both group were compared.

    RESULTS: There was no significant difference in the efficacy index between the two groups(P>0.05), and the safety index of group A was higher than that of group B(P<0.05). The number of patients with UCVA and BCVA greater ≥1.0 after surgery in both groups were increased, while the diopter decreased, and the difference between the two groups was not statistically significant(P>0.05). Compared with preoperative, there was no significant difference in the contrast sensitivity between the visual acuity, scotopic glare and glare in group A(P>0.05). Compared with group A, the visual sensitivity, glare-free glare and glare contrast sensitivity values of group B decreased, and the differences between groups and groups were statistically significant(P<0.05). There was no significant difference in the incidence of complications between the two groups(P>0.05).

    CONCLUSION: PPCIOL and femtosecond laser LASIK can effectively correct the vision of patients with high myopia, but PPCIOL has less influence on high-order aberrations and contrast sensitivity, and has more advantages in postoperative visual quality.

    Reference
    Related
    Cited by
Get Citation

Ya Deng, Li-Fang Lu, Juan Xu, et al. Comparison of early visual quality between PPCIOL implantation and femtosecond laser LASIK. Guoji Yanke Zazhi( Int Eye Sci) 2019;19(4):559-562

Copy
Share
Article Metrics
  • Abstract:
  • PDF:
  • HTML:
  • Cited by:
Publication History
  • Received:November 27,2018
  • Revised:March 13,2019
  • Adopted:
  • Online: March 22,2019
  • Published: