Efficacy and safety of Ahmed glaucoma valve implantation with lens extraction in neovascular glaucoma with cataract
Author:
Corresponding Author:

Affiliation:

Clc Number:

Fund Project:

National Natural Science Foundation of China(No.U1904166); Henan Provincial Science and Technology Program(No.SBGJ2018072)

  • Article
  • |
  • Figures
  • |
  • Metrics
  • |
  • Reference
  • |
  • Related
  • |
  • Cited by
  • |
  • Materials
  • |
  • Comments
    Abstract:

    AIM:To assess the efficacy of Ahmed glaucoma valve implantation combined with lens extraction for neovascular glaucoma(NVG)with cataract.

    METHODS: A retrospective comparative study was designed. 93 patients with NVG were enrolled. All patients received preoperative anti-vascular endothelial growth factor(VEGF)injections, 41 eyes underwent Ahmed glaucoma valve(AGV)implantation only, and 52 eyes underwent AGV implantation and lens extraction by phacoemusification. The best corrected visual acuities(BCVA), intraocular pressure(IOP), and surgical complications were evaluated.

    RESULTS: Postoperative visual acuity was improved in 16 eyes(39%), decreased in 14 eyes(34%), unchanged in 11 eyes(27%)in group 2, and 15 eyes(29%)improved,24 eyes(46%)decreased, 13 eyes(25%)unchanged in group 1 respectively(P>0.05). The group 2 demonstrated an 51% complete and 22% qualified success rate and 27% failure rate, and the 44% complete and 25% qualified success rate and 31% failure rate in group 1(P>0.05). Among the complications, fibrous exudation(56%)was the first, hyphema(46%)came second in group 2, while shallow anterior chamber(35%)was the most, fibrous exudations(31%)and anterior chamber hyphema(25%)followed in the group 1. And no tube extrusion serious complication had occurred in both groups(P<0.05). No significant differences in postoperative complications were observed between the groups(P>0.05).

    CONCLUSION: For NVG with cataract, AGV implantation with lens extraction is a priority for reduction of IOP and improvement of visual acuity.

    Reference
    Related
    Cited by
Get Citation

Hai-Jun Li, Jing Ren, Liang Dong, et al. Efficacy and safety of Ahmed glaucoma valve implantation with lens extraction in neovascular glaucoma with cataract. Guoji Yanke Zazhi( Int Eye Sci) 2021;21(2):331-334

Copy
Share
Article Metrics
  • Abstract:
  • PDF:
  • HTML:
  • Cited by:
Publication History
  • Received:April 18,2020
  • Revised:December 28,2020
  • Adopted:
  • Online: January 19,2021
  • Published: