Clinical application of OPD-Scan Ⅲ aberration analyzer in evaluating the implantation of trifocal intraocular lens in patients with high myopia complicated with cataract
Author:
Fund Project:

Science and Technology Program of Foshan, Guangdong Province(No.2018AB000381)

  • Article
  • | |
  • Metrics
  • |
  • Reference [18]
  • |
  • Related [20]
  • | | |
  • Comments
    Abstract:

    AIM: To evaluate the visual quality of patients with high myopia complicated with cataract after implantation of trifocal intraocular lens by OPD-Scan Ⅲ aberration analyzer.

    METHODS: Totally 32 patients(38 eyes)with high myopia complicated with cataract who underwent femtosecond laser assisted cataract phacoemulsification combined with trifocal intraocular lens implantation in Foshan Aier Eye Hospital from June 2018 to December 2020 were selected. Uncorrected distance visual acuity(UCDVA), uncorrected intermediate visual acuity(UCIVA)and uncorrected near visual acuity(UCNVA)were compared before, and 1wk, 3mo after surgery; OPD-Scan Ⅲ aberration analyzer measured objective visual quality before, and 1wk and 3mo after surgery.

    RESULTS: There were significant differences in UCDVA, UCIVA and UCNVA before, and 1wk, 3mo after operation(P<0.05). The average orientation and centration distance was 0.12(0.08-0.15)mm and the average axial was(212.68±90.45)°in 3mo postoperative. There were significant differences in spherical aberration(P<0.05), Strehl ratio(SR)and area ratio(AR)before, and 1wk, 3mo after operation(P<0.001). In comparison, SR at 1wk and 3mo postoperative was higher than that before operation, whereas AR in 1wk and 3mo postoperative were both higher than that before operation(all P<0.001). There was a negative correlation between SR and spherical aberration at 3mo postoperative(rs=-0.420, P<0.01); There was a negative correlation between SR and trefoil at 3mo postoperative(rs= -0.418, P<0.01); There was a negative correlation between AR and trefoil at 3mo postoperative(rs=-0.400, P<0.05).

    CONCLUSION: Femtosecond laser assisted cataract surgery combined with trifocal intraocular lens implantation can provide a comfortable and natural full-range vision. The orientation and centricity of trifocal intraocular lens using OPD-Scan Ⅲ has shown that there was a good reliability and consistency. The vision quality using OPD-Scan Ⅲ is satisfactory.

    Reference
    1李海燕, 郭琳, 杨文, 等. 微切口无黏弹剂有晶状体眼后房型人工晶状体植入术治疗高度近视. 眼科新进展 2019; 39(6):544-548
    2 Rabsilber TM, Kretz FT, Holzer MP, et al. Bilateral implantation of toric multifocal additive intraocular lenses in pseudophakic eyes. J Cataract Refract Surg 2012; 38(8):1495-1498
    3刘一昀, 孙彤, 高玉菲, 等. OPD-Scan Ⅲ型屈光分析仪在评估SBL-3型多焦点人工晶状体中的应用. 中华眼科医学杂志(电子版)2019; 9(3):153-159
    4 Ikuno Y. Overview of the complications of high myopia. Retina 2017; 37(12):2347-2351
    5 Ogawa T, Shiba T, Tsuneoka H. Usefulness of implantation of diffractive multifocal intraocular lens in eyes with long axial lengths. J Ophthalmol 2015; 2015:956046
    6 Brar S, Ganesh S, Rp N, et al. Clinical outcomes and patient satisfaction with a new diffractive-refractive trifocal intraocular lens - A 12 month prospective study. Clin Ophthalmol Auckl N Z 2021; 15:3247-3257
    7 Sungsoon H, Dong Hui L, Joo H, et al. Myopic shift after implantation of a novel diffractive trifocal intraocular lens in korean eyes. Korean J Ophthalmol 2018; 32(1):16-22
    8 Steinwender G, Schwarz L, Böhm M, et al. Visual results after implantation of a trifocal intraocular lens in high myopes. J Cataract Refract Surg 2018; 44(6):680-685
    9陈静敏,王立.后房型人工晶状体的位置对视觉质量的影响.国际眼科杂志 2014; 14(12):2172-2175
    10 Ebrahim J, Hassan H, Tahereh A, et al. Comparison of ocular aberrations in two hydrophobic and hydrophilic intraocular lenses. Eye Contact Lens 2015; 41(5):287-290
    11 Zhu X, He W, Zhang Y, et al. Inferior decentration of multifocal intraocular lenses in myopic eyes. Am J Ophthalmol 2018; 188:1-8
    12 Meng JQ, He WW, Rong XF, et al. Decentration and tilt of plate-haptic multifocal intraocular lenses in myopic eyes. Eye Vis(Lond) 2020; 7: 17
    13 Kata M,Knorz Michael C,Alió Jorge L, et al. Internal aberrations and optical quality after femtosecond laser anterior capsulotomy in cataract surgery. J Refract Surg 2011; 27(10):711-716
    14王志亮,陈志敏,许衍辉,等.清除LECs对高度近视合并白内障患者囊袋稳定性的影响.国际眼科杂志 2020; 20(2):294-296
    15刘玉璞,李雪冬,鲁媛媛,等.高度近视眼后房型ICL植入术后波前像差的改变.国际眼科杂志2013; 13(3):462-465
    16周龚莉,王勇.中老年白内障患者中角膜高阶波前像差与眼轴长度相关性变化.临床眼科杂志2016; 24(6):510-513
    17 Zheng YZ, Chen YP, Qiu Y, et al. Analysis of the optical quality by determining the modulation transfer function for anterior corneal surface in myopes. Int J Ophthalmol 2012; 5(2):196-201
    18高敬,周珺,王肖,等.儿童散光度数变化对波前像差的影响.眼科新进展2017; 37(4):365-368
    Cited by
    Comments
    Comments
    分享到微博
    Submit
Get Citation

Shu-Yu Zhao, Jin-Xian He, Yan-Chun Wu,/et al.Clinical application of OPD-Scan Ⅲ aberration analyzer in evaluating the implantation of trifocal intraocular lens in patients with high myopia complicated with cataract. Guoji Yanke Zazhi( Int Eye Sci) 2022;22(2):318-321

Copy
Share
Article Metrics
  • Abstract:874
  • PDF: 1340
  • HTML: 0
  • Cited by: 0
Publication History
  • Received:August 23,2021
  • Revised:December 26,2021
  • Online: January 27,2022