Evaluation of early binocular visual function after implantable collamer lens V4c implantation in patients with high myopia
Author:
Corresponding Author:

Affiliation:

Clc Number:

Fund Project:

Natural Science Foundation Enterprise Joint Fund Project of Hunan Province(No.2023JJ70040); Young and Middle-aged Science and Technology Innovation Incubation Project of Aier Eye Group(No.AC2214D01); Clinical Research Institute Research Fund Project of Aier Eye Group(No.AR2002D8)

  • Article
  • |
  • Figures
  • |
  • Metrics
  • |
  • Reference
  • |
  • Related
  • |
  • Cited by
  • |
  • Materials
  • |
  • Comments
    Abstract:

    AIM: To evaluate the binocular visual function in high myopia patients after the implantation of implantable collamer lens(ICL)V4c.

    METHODS: A total of 35 cases(70 eyes)that received binocular ICL implantation at our hospital from May 2019 to May 2021 were enrolled in this prospective study. Binocular full-range visual acuity, contrast sensitivity, stereopsis, mesopic vision and glare sensitivity, and monocular wavefront and the quality of vision questionnaire were assessed before the surgery and at 1 mo postoperatively.

    RESULTS: At 1 mo postoperatively, 35 cases(100%)had binocular uncorrected distance visual acuity(UDVA)≤0.00(LogMAR), 16 cases(46%)had binocular UDVA≥preoperative corrected distance visual acuity(CDVA). Binocular UDVA and uncorrected intermediate visual acuity(UIVA,80 cm)were improved compared to preoperative CDVA and distance-corrected intermediate visual acuity(DCIVA,80 cm)(all P<0.05).While there were no differences in the binocular postoperative UIVA(60 cm)and preoperative DCIVA(60 cm),and uncorrected near visual acuity(UNVA,40 cm)and preoperative distance-corrected near visual acuity(DCNVA,40 cm)(all P>0.05). The binocular contrast sensitivity was significantly improved postoperatively(P=0.001), and the postoperative binocular mesopic vision, glare sensitivity(no glare/glare)and binocular stereopsis(5 m/40 cm)had no differences(all P>0.05). The postoperative total higher-order aberration, trefoil aberration, coma and spherical aberration were increased, besides the median of total coma in the right eye with a pupil diameter of 3.0 mm was decreased after surgery. The mean total score of quality of vision questionnaire was significantly increased from 54.87 preoperatively to 80.92 after implantation(P<0.05), with high satisfaction and no obvious visual disturbance in patients.

    CONCLUSION: Although the monocular high-order aberrations increased in the early stage after ICL V4c binocular implantation in patients with high myopia, the binocular visual function was improved.

    Reference
    Related
    Cited by
Get Citation

Tang Kaili, Wang Jing, Zhao Zhenbo, et al. Evaluation of early binocular visual function after implantable collamer lens V4c implantation in patients with high myopia. Guoji Yanke Zazhi( Int Eye Sci) 2024;24(4):634-640

Copy
Share
Article Metrics
  • Abstract:
  • PDF:
  • HTML:
  • Cited by:
Publication History
  • Received:September 01,2023
  • Revised:March 06,2024
  • Adopted:
  • Online: March 21,2024
  • Published: