Comparison of bilateral implantation of extended depth-of-focus intraocular lens and mix-and-match implantation of extended depth-of-focus intraocular lens with a diffractive bifocal intraocular lens
Author:
Corresponding Author:

Affiliation:

Clc Number:

Fund Project:

The Jilin Health Technology Innovation Project(No.2020J038); Jilin Province Science and Technology Development Program(No.20200801026GH)

  • Article
  • |
  • Figures
  • |
  • Metrics
  • |
  • Reference
  • |
  • Related
  • |
  • Cited by
  • |
  • Materials
  • |
  • Comments
    Abstract:

    AIM: To compare the clinical outcomes of extended depth-of-focus intraocular lenses(EDOF IOLs)using either micromonovision implantation or mixed implantation of EDOF and diffractive bifocal IOLs.

    METHODS: This retrospective clinical trial included 130 patients(260 eyes), who were divided into two groups. Group RR comprised 70 patients(140 eyes)bilaterally implanted with ZXR00 IOLs(Tecnis ZXR00, where one target was -0.5 D to -0.75 D and the other was 0 to -0.25 D). Group RM comprised 60 patients(120 eyes)unilaterally implanted with both ZXR00 and ZMB00 IOLs(Tecnis ZMB00, 0 to -0.25 D). Postoperative outcomes were compared after 3 mo, including visual acuity, defocus curves, stereoacuity, modulation transfer functions(MTFs), higher-order aberrations, and Visual Function-14(VF-14)questionnaire responses.

    RESULTS: Group RR had superior bilateral intermediate vision, while the group RM had superior bilateral near vision(both P<0.05). Group RM also exhibited superior MTFs and reduced higher-order aberrations(both P<0.05). Stereoacuity and VF-14 questionnaire results showed no statistically significant difference between groups(P>0.05).

    CONCLUSION: The implantation of micromonovision has significantly improved near vision. IOLs and their collocation can be customized according to individual patient needs to achieve precise treatment and provide cataract patients with high-quality vision.

    Reference
    Related
    Cited by
Get Citation

Li Tong, Li Zhuoya, Guo Rong, et al. Comparison of bilateral implantation of extended depth-of-focus intraocular lens and mix-and-match implantation of extended depth-of-focus intraocular lens with a diffractive bifocal intraocular lens. Guoji Yanke Zazhi( Int Eye Sci) 2025;25(3):337-343

Copy
Share
Article Metrics
  • Abstract:
  • PDF:
  • HTML:
  • Cited by:
Publication History
  • Received:September 22,2024
  • Revised:December 13,2024
  • Adopted:
  • Online: February 19,2025
  • Published: