Efficacy and safety of high-dose ultrasound cyclo-plasty procedure in refractory glaucoma
Author:
Contact Author:

Li-Ming Tao. Department of Ophthalmology, the Second Affiliated Hospital of Anhui Medical University, Hefei 230601, Anhui Province, China. lhtay@126.com

Affiliation:

Clc Number:

Fund Project:

Supported by the Anhui Medical University Research Fund Project (No.2018xkj042); the Second Hospital of Anhui Medical University Incubation Project of NSFC (No.2019GQFY04); Science and Technology New Star Training Project (No.2018KA08).

  • Article
  • |
  • Figures
  • |
  • Metrics
  • |
  • Reference
  • |
  • Related
  • |
  • Cited by
  • |
  • Materials
  • |
  • Comments
    Abstract:

    AIM: To evaluate the efficacy and safety of high-dose ultrasound cyclo-plasty (UCP) for the treatment of refractory glaucoma in Chinese patients. METHODS: In this 6-month retrospective study, 37 eyes of 37 patients suffering from severe glaucoma with uncontrolled intraocular pressure (IOP) of ≥21 mm Hg underwent 8-s ultrasonic cyclocoagulation with ten active piezoelectric elements. A complete ophthalmic examination was performed before and at 1d, 1, 3, 6mo after UCP. Therapeutic success was defined as IOP reduction from baseline ≥20% and IOP ≥5 mm Hg without adding new glaucoma medication compare to baseline at the 6-month follow-up visit. In addition to mean IOP at each follow-up visit, medications used and complications were also detected and compared to baseline. RESULTS: After UCP procedure, the mean IOP was significantly reduced (P<0.01) from the preoperative 44.1±11.9 mm Hg to postoperative 26.7±11.8 mm Hg at 3mo, and 30.4±14.5 mm Hg at 6mo. The overall mean IOP reductions achieved at 3 and 6mo were 39% and 31% compared to baseline IOP. Sixty-one percent of patients responded well to UCP treatment with a mean IOP reduction of 48% at 3mo and 42% at 6mo. Ocular pain in most of patients were alleviated. No serious intraoperative or postoperative complications occurred. CONCLUSION: High-dose UCP treatment is an effective and safe procedure to reduce IOP in Chinese patients with severe glaucoma.

    Reference
    Related
    Cited by
Get Citation

He-Ting Liu, Qing Zhang, Zheng-Xuan Jiang, et al. Efficacy and safety of high-dose ultrasound cyclo-plasty procedure in refractory glaucoma. Int J Ophthalmol, 2020,13(9):1391-1396

Copy
Share
Article Metrics
  • Abstract:
  • PDF:
  • HTML:
  • Cited by:
History
  • Received:February 11,2020
  • Revised:May 08,2020
  • Adopted:
  • Online: July 21,2020
  • Published: