Assessment of anterior chamber angle changes after phacoemulsification with swept-source OCT
Author:
Corresponding Author:

Yun-E Zhao. Eye Hospital and School of Ophthalmology and Optometry, Wenzhou Medical University, Wenzhou 325027, Zhejiang Province, China. zyehzeye@126.com

Affiliation:

Clc Number:

Fund Project:

  • Article
  • |
  • Figures
  • |
  • Metrics
  • |
  • Reference
  • |
  • Related
  • |
  • Cited by
  • |
  • Materials
  • |
  • Comments
    Abstract:

    AIM: To assess the changes of anterior chamber angle in patients with shallow anterior chamber after phacoemulsification combined with intraocular lens (IOL) implantation, based on anterior segment swept-source optical coherence tomography (AS-SS-OCT) measurements. METHODS: This was a prospective case control study; sixty eyes of sixty case were scheduled for cataract surgery with normal intraocular pressure (IOP). Based on anterior chamber depth (ACD) and gonioscopy findings, the eyes were divided into two groups: group of shallow anterior chamber and narrow angle (SAC group, 30 eyes); and group of normal anterior chamber group with wide angle (NAC group, 30 eyes). Measurements of ACD, anterior chamber volume (ACV), iris volume (IV), lens vault (LV), angle opening distance (AOD), angle recess area (ARA), trabecular iris space area (TISA), and trabecular iris angle (TIA) were conducted in each group before and 3mo after surgery. RESULTS: There was no significant difference in age, axial length (AL), corneal curvature, corneal diameter, intraocular pressure, and IV between two groups before surgery, except for the LV (P=0.000). ACD and ACV were prominently larger in the NAC group than the SAC group 3mo after operation (3.69±0.38 vs 3.85±0.39 mm, P=0.025; 161.37±19.47 vs 178.26±20.30 mm3, P=0.002). AOD750, ARA750 in nasal and inferior quadrants, TISA750 in all quadrants except temporal, and TIA750 in all quadrants in SAC group were significantly smaller than those in NAC group after operation (all P<0.05). CONCLUSION: Cataract surgery can deepen anterior chamber and increase the width of anterior chamber angle in Chinese subjects, but the angle related parameters including AOD750, ARA750, TISA750, TIA, TISA750, and ACV in patients with shallow anterior chamber and narrow angle do not reach the normal level.

    Reference
    Related
    Cited by
Get Citation

Qian Zheng, Man Hu, Zhang-Liang Li, et al. Assessment of anterior chamber angle changes after phacoemulsification with swept-source OCT. Int J Ophthalmol, 2021,14(10):1527-1532

Copy
Share
Article Metrics
  • Abstract:
  • PDF:
  • HTML:
  • Cited by:
Publication History
  • Received:November 06,2020
  • Revised:March 25,2021
  • Adopted:
  • Online: September 23,2021
  • Published: