Abstract:AIM: To detect an earlier improvement in mild to moderate keratoconus following corneal cross-linking (CXL) with total corneal refractive power (TCRP) using ray tracing method. METHODS: A total of 40 eyes of 30 consecutive patients who underwent CXL for progressive keratoconus were retrospectively enrolled. The following keratometric parameters provided by Pentacam HR, including maximum keratometry (Kmax), steepest keratometry (Ksteep), 3 mm zonal TCRP centered over corneal apex (TCRPapex,zone 3 mm), zonal mean keratometry and TCRP centered over corneal cone (Kmcone,zone and TCRPcone,zone 1, 2, 3 mm) were evaluated preoperatively and 1, 3, 6, and 12mo postoperatively. Groups 1 and 2 were defined based on Kmax at postoperative 1mo as improved (the initial improvement group) or worsen (the initial deterioration group) compared to the preoperative level. RESULTS: In the overall group, only keratometric parameters based on ray tracing method displayed significant improvement early at 3mo postoperatively, in which TCRPcone,zone 1 mm and 2 mm exhibited the largest flattening (0.57 D and 0.53 D, respectively). In Group 1, only Kmax, Kmcone,zone 2 mm and TCRPcone,zone 2 mm showed significant improvement initially at 1mo postoperatively, in which Kmax exhibited the largest improvement (1.05 D), followed by TCRPcone,zone 2 mm (0.82 D). In Group 2, only keratometric parameters based on ray tracing method and Kmcone,zone 3 mm showed slight but not significant improvement early at 3mo, in which TCRPcone,zone 3 mm displayed the most improvement (0.19 D), followed by TCRPcone,zone 2 mm (0.15 D). CONCLUSION: The findings indicate that a 2 mm zonal TCRP centered over Kmax could earlier detect keratometric improvement by CXL compared to other commonly used parameters in mild to moderate keratoconic eyes.