Rotational stability of plate haptic toric intraocular lenses after combined 25-gauge vitrectomy and cataract surgery
Author:
Contact Author:

Siegfried G. Priglinger. Department of Ophthalmology, University Hospital, LMU Munich, Mathildenstra?e 8, Munich 80336, Germany. siegfried.priglinger@med.uni-muenchen.de

Affiliation:

Clc Number:

Fund Project:

  • Article
  • |
  • Figures
  • |
  • Metrics
  • |
  • Reference
  • |
  • Related
  • |
  • Cited by
  • |
  • Materials
  • |
  • Comments
    Abstract:

    AIM: To evaluate the postoperative intraocular lens (IOL) rotational stability and residual refractive astigmatism following combined 25-gauge vitrectomy and cataract surgery with implantation of a plate haptic toric IOL. METHODS: In this retrospective case series, 32 eyes of 32 patients underwent a combined 25-gauge vitrectomy and phacoemulsification for vitreoretinal diseases and cataract with regular corneal astigmatism of at least 1 diopter (D). A plate haptic toric IOL (AT Torbi 709M, Carl Zeiss Meditec AG) was implanted in all eyes. The outcome measures were rotational stability and refractive astigmatism up to 6mo postoperatively as well as the best corrected visual acuity (BCVA). RESULTS: Preoperative refractive astigmatism was 2.14±1.17 D, which was significantly reduced to 0.77±0.37 D six to eight weeks postoperatively and remained stable throughout the observation period (0.67±0.44 D at three months and 0.75±0.25 D at six months; for all groups: P<0.0001 compared to baseline). BCVA improved significantly from 0.36±0.33 logMAR preoperatively to 0.10±0.15 logMAR following surgery (P=0.02). Mean IOL axis deviation from the target axis was 3.4°±2.9° after six to eight weeks and significantly decreased over time (2.4°±2.6° six months after surgery; P=0.04). In one patient IOL, re-alignment was performed. CONCLUSION: Corneal astigmatism is significantly reduced following combined 25-gauge vitrectomy and cataract surgery. The plate haptic toric IOL position and axis remain stable during the observation period of six months.

    Reference
    Related
    Cited by
Get Citation

Lara Buhl, Julian Langer, Stefan Kassumeh, et al. Rotational stability of plate haptic toric intraocular lenses after combined 25-gauge vitrectomy and cataract surgery. Int J Ophthalmol, 2023,16(8):1231-1236

Copy
Share
Article Metrics
  • Abstract:
  • PDF:
  • HTML:
  • Cited by:
History
  • Received:October 03,2022
  • Revised:June 21,2023
  • Adopted:
  • Online: July 25,2023
  • Published: