Practical method to calculate post-LASIK corneal power: the Actual Ka+p method
Author:
Contact Author:

Affiliation:

Clc Number:

Fund Project:

Shanghai Leading Academic Discipline Project ,China(No. S30205)

  • Article
  • |
  • Figures
  • |
  • Metrics
  • |
  • Reference
  • |
  • Related
  • |
  • Cited by
  • |
  • Materials
  • |
  • Comments
    Abstract:

    AIM: To evaluate the accuracy of a practical method (the Actual Ka+p method) of corneal power measurement for post-LASIK eyes undergoing cataract surgery. METHODS: Ten eyes of 7 patients (4 male, 3 female, average age 50.10±4.01 years, with -11.01±3.55D mean refraction before LASIK), underwent post-LASIK phaco+IOL cataract surgery. We used the posterior corneal curvature as measured by the Pentacam in a method we named Actual Ka+p to calculate the post-LASIK corneal power for IOL calculation. The refractive outcomes after cataract surgery were evaluated. The Actual Ka+p was compared with the back- calculated corneal power (BCK), which was thought to be the benchmark of true corneal power. The corneal power estimated by other published methods, including Maloney, Shammas, Koch-Maloney, Savini, and McCulley, together with the true net power and equivalent K reading (EKR) as found by the Pentacam were also compared with the BCK. RESULTS: All eyes achieved satisfied refractive status after cataract surgery. The difference between the postoperative refraction and the target refraction was 0.04±0.40D, range from -0.63D and +0.85D. Among all the methods we studied, although the Bonferroni multiple comparison tests did not detect significant differences between any two of them, the Actual Ka+p yielded the highest agreement with the BCK, with 80% of the eyes falling within ±0.5D and 100% within ±1.0D from the BCK values. CONCLUSION: The Actual Ka+p method can provide encour- aging results in post-LASIK eyes undergoing cataract surgery.

    Reference
    Related
    Cited by
Get Citation

Yi-Qian Hu, Xiang-Yu Ye, Xiu-Li Zhou, et al. Practical method to calculate post-LASIK corneal power: the Actual Ka+p method. Int J Ophthalmol, 2010,3(4):337-341

Copy
Share
Article Metrics
  • Abstract:
  • PDF:
  • HTML:
  • Cited by:
History
  • Received:
  • Revised:
  • Adopted:
  • Online:
  • Published: