Comparison of retinal nerve fiber layer and macular thickness measurements with Stratus OCT and OPKO/OTI OCT devices in healthy subjects
Author:
Contact Author:

Affiliation:

Clc Number:

Fund Project:

  • Article
  • |
  • Figures
  • |
  • Metrics
  • |
  • Reference
  • |
  • Related
  • |
  • Cited by
  • |
  • Materials
  • |
  • Comments
    Abstract:

    AIM: To compare retinal nerve fiber layer (RNFL) and macular thickness measurements obtained with the Stratus optical coherence tomography (OCT) and OPKO/OTI OCT devices. METHODS: Included in the study were 59 eyes of 30 participants. All measurements for each eye were done on the same day with both devices. Student’s paired t-tests were used to compare the central macular thickness and RNFL measurements of the Stratus OCT and OPKO/OTI OCT. Pearson correlation was used to assess the relationship between the devices. Coefficient of variation (COV) was calculated to assess intersession repeatability. RESULTS: Using both the Stratus OCT and OPKO/OTI OCT, respectively, the measured mean average RNFL thicknesses were 98.9±11.1 μm and 115.1±9.6 μm (P=0.001), and the measured mean central retinal thicknesses (CRT) were 196.2±18.8 μm and 204.5±21.1 μm (P<0.001). Measured by the two devices, the RNFL thickness values were correlated in all quadrants, as were the retinal thickness values except the inferior outer sector. COV for average RNFL and CRT thickness were 2.9% and 4.6% for Stratus OCT, and 2.1% and 4.2% for OPKO/OTI OCT, respectively. CONCLUSION: We found good reproducibility of RNFL and retina thickness measurements for both Stratus OCT and OPKO/OTI OCT devices. However, even though the two OCT systems provided statistically correlated results, the values for both RNFL and macular thickness were statistically different. RNFL and macular thickness measurements with the OPKO/OTI OCT were higher than that of the Stratus OCT; therefore, the two OCT systems cannot be used interchangeably for the measurements of RNFL and macular thickness.

    Reference
    Related
    Cited by
Get Citation

Ahmet Ozkok, Julide Canan Umurhan Akkan, Nevbahar Tamcelik, et al. Comparison of retinal nerve fiber layer and macular thickness measurements with Stratus OCT and OPKO/OTI OCT devices in healthy subjects. Int J Ophthalmol, 2015,8(1):98-103

Copy
Share
Article Metrics
  • Abstract:
  • PDF:
  • HTML:
  • Cited by:
History
  • Received:January 07,2014
  • Revised:April 30,2014
  • Adopted:April 30,2014
  • Online: February 13,2015
  • Published: