    AIM: To evaluate the stability of neodymium (Nd):YAG laser posterior capsulotomy in eyes with capsular tension rings (CTRs). METHODS: A total of 60 eyes that underwent cataract surgery and laser posterior capsulotomy postoperatively were included in this retrospective cohort study. To evaluate the safety and stability of capsulotomy, changes in the size of posterior capsulotomy and anterior chamber depth (ACD) in three groups: the group without CTR, the group with 12 mm CTRs, and the group with 13 mm CTRs, at 1wk, 3, 12, and 15mo after capsulotomy, were compared. RESULTS: In the group without CTR and the group with 12 mm CTR, there was no significant change in ACD at every post-laser follow-up. In the group with 13 mm CTR, the ACD change was significant until 3mo after capsulotomy. In all groups, there was a significant increase in the area of capsulotomy between 1wk and 3mo post-laser. Between 3 and 12mo post-laser, only the group with 13 mm CTR showed a significant increase in the area of capsulotomy (P<0.01). CONCLUSION: Laser posterior capsulotomy is safe in all three groups. The capsulotomy and ACD become stabilized and have not shown significant changes since 1y post-laser, even with larger CTRs. The maintenance of centrifugal capsular tension can last longer with larger CTRs, and the stability of the capsulotomy site can be reached about 12mo after capsulotomy in pseudophakic eyes with larger CTRs.

    Reference
    1 Ucar F, Cetinkaya S. Posterior capsular vacuuming to avoid PCO formation. Int Ophthalmol 2022;42(10):3089-3095.
    2 Haripriya A, Ramulu PY, Schehlein EM, Shekhar M, Chandrashekharan S, Narendran K, Venkatesh R, Sithiq M, Ramakrishnan R, Ravindran RD, Robin AL. The aravind pseudoexfoliation study: 5-year postoperative results. the effect of intraocular lens choice and capsular tension rings. Am J Ophthalmol 2020;219:253-260.
    3 Schartmüller D, Schriefl S, Schwarzenbacher L, Leydolt C, Kundi M, Pieh S, Menapace R, Kriechbaum K. Posterior capsule opacification and Nd:YAG laser rates with two hydrophobic acrylic single-piece IOLs. Eye (Lond) 2020;34(5):857-863.
    4 Liu HY, Liu XJ, Chen YT, Wang DF, Li YS, Chen HJ, Ma XL. Effect of Nd:YAG laser capsulotomy on the risk for retinal detachment after cataract surgery: systematic review and meta-analysis. J Cataract Refract Surg 2022;48(2):238-244.
    5 Kim JS, Kang MJ, Jeong KD, Hwang JH. Haptic fracture and dislocation of polyimide intraocular lens after neodymium:YAG laser capsulotomy: a case report. Medicine (Baltimore) 2019;98(20):e15720.
    6 Kang KT, Kim YC. Dislocation of polyfocal full-optics accommodative intraocular lens after neodymium-doped yttrium aluminum garnet capsulotomy in vitrectomized eye. Indian J Ophthalmol 2013;61(11): 678-680.
    7 Kim TY, Kang HG, Kim CY, Koh HJ, Kim SS, Kim M. Delayed vitreous prolapse after cataract surgery: clinical features and surgical outcomes. Sci Rep 2021;11(1):16107.
    8 Monteiro T, Soares A, Dourado Leite R, Franqueira N, Faria-Correia F, Vaz F. Comparative study of induced changes in effective lens position and refraction after Nd:YAG laser capsulotomy according to intraocular lens design. Clin Ophthalmol 2018;12:533-537.
    9 Yang SF, Jiang H, Nie KL, Feng LW, Fan W. Effect of capsular tension ring implantation on capsular stability after phacoemulsification in patients with weak zonules: a randomized controlled trial. CTR implantation in cataract patients with weak zonules. BMC Ophthalmol 2021;21(1):19.
    10 Elmohamady MN, Elhabbak A, Gad EA. Circular YAG laser anterior capsulotomy for anterior capsule contraction syndrome. Int Ophthalmol 2019;39(11):2497-2503.
    11 Congdon N, Fan H, Choi K, et al. Impact of posterior subcapsular opacification on vision and visual function among subjects undergoing cataract surgery in rural China: study of Cataract Outcomes and Up-Take of Services (SCOUTS) in the Caring is Hip Project, report 5. Br J Ophthalmol 2008;92(5):598-603.
    12 Maedel S, Evans JR, Harrer-Seely A, Findl O. Intraocular lens optic edge design for the prevention of posterior capsule opacification after cataract surgery. Cochrane Database Syst Rev 2021;8(8):CD012516.
    13 Zhang KK, Dong YC, Zhao MS, Nie LL, Ding XF, Zhu C. The effect of capsule tension ring on posterior capsule opacification: a meta-analysis. PLoS One 2021;16(3):e0246316.
    14 El-Haddad NSEM. The impact of Nd:YAG laser posterior capsulotomy by the use of “the circular pattern with vitreous strand cut” technique on anterior chamber parameters. Lasers Med Sci 2019;34(2):353-357.
    15 Tan Y, Zhang JQ, Li W, Jin GM, Luo LX, Liu ZZ. Refraction shift after Nd: YAG posterior capsulotomy in pseudophakic eyes: a systematic review and meta-analysis. J Refract Surg 2022;38(7):465-473.
    16 Delgado João M, Costa JV, Monteiro T, Franqueira N, Faria Correia F, Vaz F. Intraocular lens position and anterior chamber parameters evaluation after Nd: YAG laser posterior capsulotomy for posterior capsular opacification using anterior segment swept-source optical coherence tomography. Clin Ophthalmol 2022;16:153-159.
    17 Kwon H, Choi A, Kim B, Jeon S. Effect of capsular tension ring on refractive outcomes in patients with implantation of the quadrifocal acrysof PanOptix TFNT00 IOL. J Refract Surg 2021;37(3):174-179.
    18 Miyata K, Kataoka Y, Matsunaga J, Honbo M, Minami K. Prospective comparison of one-piece and three-piece tecnis aspheric intraocular lenses: 1-year stability and its effect on visual function. Curr Eye Res 2015;40(9):930-935.
    19 Findl O, Hirnschall N, Nishi Y, Maurino V, Crnej A. Capsular bag performance of a hydrophobic acrylic 1-piece intraocular lens. J Cataract Refract Surg 2015;41(1):90-97.
    20 Hawlina G, Perovšek D, Drnovšek-Olup B, MoŽina J, Gregorčič P. Optical coherence tomography for an in-vivo study of posterior-capsule-opacification types and their influence on the total-pulse energy required for Nd: YAG capsulotomy: a case series. BMC Ophthalmol 2014;14:131.
    21 Levy JH, Pisacano AM, Anello RD. Displacement of bag-placed hydrogel lenses into the vitreous following neodymium: YAG laser capsulotomy. J Cataract Refract Surg 1990;16(5):563-566.
    22 Petersen AM, Bluth LL, Campion M. Delayed posterior dislocation of silicone plate-haptic lenses after neodymium: YAG capsulotomy. J Cataract Refract Surg 2000;26(12):1827-1829.
    23 Reddy JC, Devta S, Vupparaboina KK, Ali MH, Vaddavalli PK. Early results of circularity and centration of capsulotomy prepared by three different methods. Int J Ophthalmol 2021;14(1):76-82.
    Cited by
    Comments
    Comments
    分享到微博
    Submit
Get Citation

Yang Kyung Cho, Min Sun Kim. ,/et al.Stability of neodymium:YAG laser posterior capsulotomy in eyes with capsular tension rings. Int J Ophthalmol, 2023,16(6):891-896

Copy
Share
Article Metrics
  • Abstract:278
  • PDF: 603
  • HTML: 0
  • Cited by: 0
Publication History
  • Received:February 16,2023
  • Revised:April 24,2023
  • Online: June 18,2023