[关键词]
[摘要]
目的:探讨飞秒激光制瓣LASIK术后角膜上皮下混浊(haze)的原因。
方法:对99例198眼采用飞秒激光制作角膜瓣LASIK术。使用Femto LDV达芬奇飞秒激光作上方带蒂角膜瓣。激光参数:脉冲频率1MHz,预定制角膜瓣厚度110μm,角膜瓣直径8.5~9.0mm。日本TOMEY SP100超声波角膜测厚仪,实际测量厚度为95~103(平均98.00)μm。
结果:发现haze 10例19眼,haze多发在光学区中央,直径约3.0~4.5mm,小部分在鼻侧。患者术后1,14d; 1,3,6mo的平均裸眼视力分别为0.82±0.24,0.94±0.16,0.98±0.17,1.0±0.26,0.97±0.13。而患者发生haze后的术后14d; 1,3,6mo之间裸眼视力比较差异无统计学意义(P>0.05),与术前最佳矫正视力(0.98±0.25)比较差异无统计学意义(P>0.05)。
结论:飞秒激光制作的薄角膜瓣与haze的发生有关,轻度的haze对患者术后的裸眼视力未产生影响。
[Key word]
[Abstract]
AIM: To investigate the dynamic response of cornea after the femtosecond laser-assisted laser
in situ keratomileusis(LASIK)and to evaluate the risk factors for interface haze formation after thin-flap femtosecond laser-assisted LASIK.
METHODS: One hundred and ninety-eight eyes of ninety-nine subjects with age from 19 to 23 years old, spherical equivalent refraction of -2.75- -12.50D and the central corneal thickness was 492 - 558 μm underwent the femtosecond laser LASIK with Femto LDV femtosecond laser-assisted LASIK for myopic correction, were analyzed from November 1, 2011 to March 31, 2012. The surgical parameters were set as follows: laser frequency 1MHz,flap diameter 8.5-9.0 mm and expected flap thickness 110μm, Japan TOMEY SP100 ultrasonic corneal thickness gauge, used for predetermining 110μm thickness for femtosecond flap, the actual measure thickness was 95-103μm, with an average of 98.00μm. And light scattering were assessed in all eyes that developed haze postoperatively.
RESULTS: Haze was observed in 19 eyes treated, the time of finding the haze was: 2 weeks in 2 cases of 4 eyes, 1 month 8 cases of 15 eyes. There were 14 eyes of grade 0.5. 5 eyes were grade 1. The haze usually occurred in the center of the optical zone, of which the diameter was about 3.0 - 4.5mm, and a small portion of it occurred in the nasal.
CONCLUSION: Interface haze is associated with an ultra thin femtosecond laser flap setting of 95-103μm and younger age among eyes following LASIK for myopia.
[中图分类号]
[基金项目]