后发性白内障患者行Nd:YAG激光术后视觉质量
CSTR:
作者:
作者单位:

作者简介:

通讯作者:

中图分类号:

基金项目:


Visual quality of patients with posterior capsular opacification after Nd:YAG laser surgery
Author:
Affiliation:

Fund Project:

  • 摘要
  • |
  • 图/表
  • |
  • 访问统计
  • |
  • 参考文献
  • |
  • 相似文献
  • |
  • 引证文献
  • |
  • 资源附件
  • |
  • 文章评论
    摘要:

    目的:探究角膜/屈光分析仪OPD-Scan III评估后发性白内障患者行Nd:YAG激光术后视觉质量。

    方法:回顾性研究。选取2021-05/2023-04于我院行Nd:YAG激光后囊膜切开术治疗的后发性白内障患者98例98眼,采用角膜/屈光分析仪OPD-Scan III获取患者高阶像差参数(彗差、球差和三叶草像差)和视觉质量参数\〖斯特列尔比(SR)和人眼调制传递函数(MTF)曲线中4 mm面积比(AR)\〗,比较患者术前,术后1 wk,3 mo时视力、高阶像差和视觉质量。

    结果:纳入患者手术前后裸眼远视力(UDVA)、裸眼中视力(UIVA)、裸眼近视力(UNVA)、彗差、球差、三叶草、SR和AR比较均有差异(均P<0.001)。术后1 wk,3 mo UDVA、UIVA、UNVA、彗差、球差、三叶草、SR和AR与术前比较均有差异(均P<0.05)。术后3 mo UDVA、UIVA、UNVA、SR和AR与术后1 wk比较均有差异(均P<0.05),术后3 mo彗差、球差、三叶草与术后1 wk比较均无差异(均P>0.05),术后3 mo球差、三叶草与SR均呈负相关(rs=-0.427,P=0.009; rs=-0.436,P=0.010),三叶草与AR呈负相关(rs=-0.406,P=0.015)。

    结论:后发性白内障患者Nd:YAG激光术后视力改善,使用角膜/屈光分析仪OPD-Scan III系统反映患者视觉质量具有较高的临床价值。

    Abstract:

    AIM: To explore the value of the corneal/refractive analyzer OPD-Scan III in assessing visual quality after Nd:YAG laser surgery in patients with posterior capsular opacification.

    METHODS: A total of 98 patients(98 eyes)with posterior capsular opacification who underwent Nd:YAG laser posterior capsulotomy in our hospital from May 2021 to April 2023 were retrospectively selected as the research subjects, and higher-order aberration parameters(coma, spherical aberration and trefoil aberration)and visual quality parameters \〖Strehl ratio(SR)and 4 mm area ratio(AR)in the human eye modulation transfer function(MTF)curve\〗 were obtained using the corneal/refractive analyzer OPD-Scan III. The patient's visual acuity, higher-order aberration parameters and visual quality before surgery, and at 1 wk and 3 mo after surgery were compared.

    RESULTS: There were statistically significant differences in uncorrected distance visual acuity(UDVA), uncorrected intermediate visual acuity(UIVA)and uncorrected near visual acuity(UNVA), coma, spherical aberration, trefoil aberration, SR and AR before and after surgery(all P<0.001), and there were statistically significant differences in UDVA, UIVA, UNVA, coma, spherical aberration, trefoil aberration, SR and AR at 1 wk and 3 mo postoperatively(all P<0.05). Additionally, there were differences in the UDVA, UIVA, UNVA, SR and AR at 3 mo postoperatively compared with those parameters at 1 wk postoperatively(all P<0.05), while there were no statistical significance in coma, spherical aberration, trefoil aberration at 3 mo postoperatively and those at 1 wk postoperatively(all P>0.05). Furthermore, the spherical aberration, trefoil aberration were negatively correlated with SR(rs=-0.427, P=0.009; rs=-0.436, P=0.010), and the trefoil aberration was negatively correlated with AR(rs=-0.406, P=0.015).

    CONCLUSION: The visual acuity of patients with posterior capsular opacification improved after Nd:YAG laser surgery, and the corneal/refractive analyzer OPD-Scan III system has a high clinical value in reflecting patient's visual quality.

    参考文献
    相似文献
    引证文献
引用本文

安通,刘颖,孙红双,等.后发性白内障患者行Nd:YAG激光术后视觉质量.国际眼科杂志, 2024,24(10):1655-1658.

复制
分享
文章指标
  • 点击次数:
  • 下载次数:
  • HTML阅读次数:
  • 引用次数:
历史
  • 收稿日期:2024-01-13
  • 最后修改日期:2024-08-23
  • 录用日期:
  • 在线发布日期: 2024-09-14
  • 出版日期:
文章二维码