圆锥角膜患者角膜交联术后角膜光密度的变化
CSTR:
作者:
作者单位:

作者简介:

通讯作者:

中图分类号:

基金项目:

北方民族大学中央高校基本科研业务费专项资金资助(No.2023XYZYX04); 宁夏自然科学基金项目(No.2023AAC03450); 宁夏重点研发项目(NO.2022BSB03042)


Changes of corneal densitometry in patients with keratoconus after corneal collagen cross-linking
Author:
Affiliation:

Fund Project:

Fundamental Research Funds for the Central Universities, North Minzu University(No.2023XYZYX04); Ningxia Natural Science Foundation(No.2023AAC03450); Key Research and Development Program of Ningxia(No.2022BSB03042)

  • 摘要
  • |
  • 图/表
  • |
  • 访问统计
  • |
  • 参考文献
  • |
  • 相似文献
  • |
  • 引证文献
  • |
  • 资源附件
  • |
  • 文章评论
    摘要:

    目的:观察圆锥角膜患者行角膜交联术后角膜光密度的变化规律。

    方法:采用回顾性研究。选取2020-04/2022-04在宁夏眼科医院确诊为进展期圆锥角膜并行角膜交联术的患者32例43眼。Pentacam分析系统将角膜分为前层(前120 μm)、中层及后层(后60 μm),并依据直径划分为直径0-2、2-6、6-10、10-12 mm及全直径范围五个区域,测量不同范围的角膜光密度。比较术前,术后1、3、6 mo角膜光密度的变化。

    结果:纳入患者术前和术后6 mo裸眼视力和最佳矫正视力及眼压比较均有差异(均P<0.05),角膜内皮细胞比较无差异(P=0.477)。在角膜前层、中层、全层的直径0-2、2-6、6-10 mm及全直径范围内,角膜光密度术后1 mo时到达峰值,术后3 mo与6 mo有所下降,但仍比术前高。角膜光密度在前层及全层范围内与Kmax正相关(r=0.164,P=0.016; r=0.152,P=0.023)。

    结论:角膜光密度在角膜交联术后1 mo时达到峰值,随后开始逐步下降,术后6 mo趋于稳定。

    Abstract:

    AIM: To observe the changes of corneal densitometry(CD)in patients with keratoconus after corneal cross-linking(CXL).

    METHODS: Retrospective study. A total of 32 patients(43 eyes)with keratoconus in Ningxia Eye Hospital from April 2020 to April 2022 were selected. Pentacam analysis system divided the cornea into three layers: anterior 120 μm, middle layer and posterior 60 μm, and divides it into five regions with diameters of 0-2, 2-6, 6-10, 10-12 mm and full diameter according to the diameter, and measures the CD in different ranges. The changes of CD were compared before operation and at 1, 3 and 6 mo after operation.

    RESULTS: There were differences in uncorrected visual acuity, best corrected visual acuity and intraocular pressure before and 6 mo after operation(all P<0.05), and there was no difference in corneal endothelial cells(P=0.477). CD reached its peak at 1 mo after operation, and decreased at 3 mo and 6 mo after operation, but it was still higher than that before operation. There is a significant positive correlation between CD and Kmax in the anterior layer and the whole layer(r=0.164, P=0.016; r=0.152, P=0.023).

    CONCLUSION: The values of CD peaked at 1 mo after CXL, then it gradually decreased, tending to become stable at 6 mo postoperatively.

    参考文献
    相似文献
    引证文献
引用本文

李帅,高洋,马丽梅,等.圆锥角膜患者角膜交联术后角膜光密度的变化.国际眼科杂志, 2024,24(12):1954-1958.

复制
分享
文章指标
  • 点击次数:
  • 下载次数:
  • HTML阅读次数:
  • 引用次数:
历史
  • 收稿日期:2024-06-09
  • 最后修改日期:2024-10-25
  • 录用日期:
  • 在线发布日期: 2024-11-13
  • 出版日期:
文章二维码