Abstract:AIM: To investigate the safety and therapeutic effectiveness of phakic iris-claw intraocular lens implantation for correction of high myopia with clear corneal incision.
METHODS: Implantation of phakic iris-claw intraocular lens through clear corneal incision was performed on 28 eyes of 20 high myopic patients under topical anaesthesia. Intraoperative and postoperative complications, visual acuity, intraocular pressure, refractive diopter, corneal endothelium, the stable of intraocular lens and the turbid level of lens were observed.
RESULTS: All cases were smoothly implanted iris-claw intraocular lens. No complications were found during the operation. The uncorrected visual acuity of post-operation was better than the best corrected visual acuity of pre-operation. The follow-up time lasted for 6mo, and the intraocular lens in all the eyes were basically in the normal position without tilting and obvious deviation. No serious complications such as cataract, uveitis, cystoid macular edema, retinal detachment were seen in all cases.
CONCLUSION: On the basis of having adept microsurgery technology, phakic iris-claw intraocular lens implantation is predictable and stable, and post-operation visual acuity is satisfying with few complications. It is a safe and effective way to treat high myopia.