正常人眼全角膜点扩散函数的分析
作者:
作者单位:

作者简介:

通讯作者:

中图分类号:

基金项目:


Analysis of the point spread function in total corneal of normal population
Author:
Affiliation:

Fund Project:

  • 摘要
  • |
  • 图/表
  • |
  • 访问统计
  • |
  • 参考文献
  • |
  • 相似文献
  • |
  • 引证文献
  • |
  • 资源附件
  • |
  • 文章评论
    摘要:

    目的:探讨不同瞳孔直径下正常人眼全角膜总像差的斯特列尔比(strehl ratio, SR)与总高阶像差SR的正常值及其与调制传递函数(modulation transfer function, MTF)的关系。

    方法:应用SIRIUS 3D角膜地形图仪对200例(400眼)进行全角膜总像差的SR和总高阶像差的SR检查,并分析相对应的均方根值(root-mean-square, RMS)。

    结果:在不同瞳孔直径组下(3.0, 5.0, 6.0, 7.0mm)全角膜总像差100'SR值为0.45±0.12, 0.25±0.06, 0.17±0.05, 0.13±0.04; 总高阶像差100'SR值为0.69±0.14, 0.34±0.07, 0.24±0.05, 0.16±0.04; 全角膜总像差200'SR值为0.45±0.12, 0.24±0.06, 0.20±0.04, 0.16±0.03; 总高阶像差200'SR值为0.70±0.13, 0.35±0.07, 0.27±0.06, 0.20±0.04,各组均逐渐变小; 全角膜总像差SR值和总高阶像差SR值与对应的RMS值之间均存在负相关性。当瞳孔直径小时,总像差SR值与MTF值的高频区相关性较高,而当瞳孔直径大时,总像差SR值与MTF值的低频区相关性较高。

    结论:正常人全角膜总像差的SR值和总高阶像差的SR值能够很好地反映其视觉质量。

    Abstract:

    AIM:To explore relationship between the normal strehl ratio(SR)values of total aberrations/SR values of total higher-order aberrations and modulation transfer function(MTF)at total corneal at different pupil diameters in normal population.

    METHODS: To exam the SR values of total aberrations and SR values of total higher-order aberrations of total corneals in 200 people(400 eyes)using SIRIUS 3D topography system and analysis the corresponding root-mean-square(RMS).

    RESULTS: The subjects with different pupil diameters(3.0, 5.0, 6.0, 7.0mm)'s exam results of total corneal were as following: SR value of total aberrations 100'(0.45±0.12),(0.25±0.06),(0.17±0.05),(0.13±0.04); SR value of total higher order ab cerrations 100'(0.69±0.14),(0.34±0.07),(0.24±0.05),(0.16±0.04); SR value of total aberrations 200'(0.45±0.12),(0.24±0.06),(0.20±0.04),(0.16±0.03); SR value of total higher order aberrations 200'(0.70±0.13),(0.35±0.07),(0.27±0.06),(0.20±0.04). The SR values of each group decreases with the increases of pupil diameters. The SR values of total aberrations and SR values of total higher-order aberrations at total corneals are negatively correlated with corresponding RMS value. When the pupil diameter is small, the SR value of total aberrations is more related to higher frequency region of MTF. When the pupil diameter is big, the SR value of total aberrations is more related to lower frequency region of MTF.

    CONCLUSION: The visual performance of normal people can be well reflected by SR values of total aberrations and SR values of total higher-order aberrations at total corneal.

    参考文献
    相似文献
    引证文献
引用本文

陈妍鹏,郭旭,郭俊红,等.正常人眼全角膜点扩散函数的分析.国际眼科杂志, 2015,15(4):577-583.

复制
分享
文章指标
  • 点击次数:
  • 下载次数:
  • HTML阅读次数:
  • 引用次数:
历史
  • 收稿日期:2014-07-19
  • 最后修改日期:2015-01-15
  • 录用日期:
  • 在线发布日期: 2015-04-08
  • 出版日期: