Abstract:AIM:To observe the efficacy and safety of anterior chamber maintainer with supplementary lens in anterior-posterior combined surgery in rabbit eyes.
METHODS:Group A: anterior chamber maintainer and supplementary lens were applied in anterior-posterior combined surgery. Group B: conventional anterior-posterior combined surgery was used. The application value of this device were analyzed from the operation time, operation effect, postoperative complications.
RESULTS:The application of anterior chamber maintainer with supplementary lens in anterior-posterior combined surgery played a positive role on the stripping time(P<0.05), but there was no significant difference on operation effect and postoperative complications(P>0.05).
CONCLUSION:There are advantages of anterior chamber maintainer with supplementary lens in anterior-posterior combined surgery, such as more convenient in operation process, a wider range of observation, bimanualness, less complications and so on.